Parker offers a wide range of pressure compensated flow controls for applications that demand constant flow with varying loads and pressures; handling pressures as high as 420 bar (6000 psi) and flows to 56 lpm (15 gpm) in a single common cavity.

Konfigurace:
Def_Configuration
Maximální provozní teplota:
> 60 to 80 °C
Průtok:
> 10 to 20 gal/min
Typ ventilu:
Pressure Compensated
Maximální provozní teplota:
> 100 to 120 °C
Maximální provozní teplota:
> 150 to 200 °C
Technologie:
Hydraulics
Průtok:
> 0 to 20 L/min
Průtok:
> 20 to 40 L/min
Maximální pracovní tlak:
> 350 to 700 bar
Maximální provozní teplota:
> 300 to 400 °F
Maximální provozní teplota:
> 150 to 200 °C
Média:
Hydraulic Oil
Maximální provozní teplota:
> 200 to 250 °F
Maximální provozní teplota:
> 80 to 100 °C
Typ upevnění:
Screw-in cartridge
Divize:
Hydraulic Valve Systems Division
Typ ventilu:
Flow Control
Maximální provozní teplota:
> 120 to 150 °C
Maximální provozní teplota:
> 300 to 400 °F
Maximální pracovní tlak:
> 5000 to 10000 psi
Maximální pracovní tlak:
> 3000 to 5000 psi
Aplikace:
Mobile
Průtok:
> 40 to 80 L/min
Funkce:
2-Way
Maximální provozní teplota:
> 250 to 300 °F
Aplikace:
Industrial
Průtok:
> 5 to 10 gal/min
Maximální pracovní tlak:
> 2000 to 3000 psi
Divize:
Mobile Hydraulic Systems Division Europe
Typ aktivace:
Mechanical
Maximální pracovní tlak:
> 200 to 350 bar
Maximální provozní teplota:
> 200 °C
Aplikace:
Hydraulic
Těsnicí materiál:
Def_Seal Material
Standardní nastavení průtoku:
Def_Standard Flow Rate Setting
Rozsah zobrazení průtoku:
Def_Flow Rate Display Range
Seřizovací mechanismus:
Def_Adjustment Mechanism
Maximální průtok:
Def_Maximum Flow Rate

Parker’s family of pressure compensated flow control valves feature a proven design that allows for a reliable and repeatable flow compensation curve throughout a wide pressure range. These valves can operate with hydraulic system flows as high as 56 lpm and pressures up to 420 bar with the option of an integrated adjustable or tuneable reverse free-flow check valve. Parker’s pressure compensated flow control valves are ideal for cylinder or motor control and/or bleed-off applications within a broad range of markets, such as the agriculture, construction, material handling, industrial, and oil & gas markets.

Markets:
• Agriculture
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
• Oil & Gas

Features/Benefits:
• Minimal flow change with pressure variation
• Reverse flow function
• Hardened working parts for maximum durability
• Tamperproof options available
• All external parts zinc plated

Applications:
• Accumulator bleed-off
• Motor speed control
• Cylinder speed control
• Power units

Additional Technical Insight:
Parker offers a wide range of spool type restrictive pressure compensated flow controls to allow for speed control of motors, cylinders, and rotary actuators. Pressure compensation allows the flow devices to maintain a constant flow even with varying loads and inlet pressures. Tunable and fully adjustable versions are available with screw or knob adjusters that can be made tamper resistant with the addition of an optional cap. FR101 is an adjustable pressure compensated flow regulator which compensates for varying loads and pressures in one direction but in the other direction flow is metered across a fixed orifice but not compensated.  In order to allow pressure compensated flow control in one direction and full free flow in the opposite direction, Parker offers an internal check valve in the adjustable FC101 cartridge.  Because both versions are tunable and not fully adjustable, the valve will need to be specified with the appropriate flow range for the application. Changes in flow rates are achieved by mechanically varying the spring force acting on a spool that has a fixed orifice and metering compensator. J02E2, J04C2, and J04E2 are fully adjustable pressure compensated flow regulators. In the opposite flow direction, those valves only meter through a fixed orifice and do not compensate. In order to achieve fully adjustable pressure compensated flow control while allowing reverse full flow, the FA101 includes an internal check valve to bypass the compensator and metering orifice.
EAN kódKonfiguraceTěsnicí materiálStandardní nastavení průtokuRozsah zobrazení průtokuSeřizovací mechanismusMaximální průtok
FR101F500KonfiguraceTěsnicí materiálStandardní nastavení průtokuRozsah zobrazení průtoku(nie je nastavené)Maximální průtok
473,99 € / kus
FR101F600KonfiguraceTěsnicí materiálStandardní nastavení průtokuRozsah zobrazení průtoku(nie je nastavené)Maximální průtok
136,58 € / kus
FR101S065KonfiguraceTěsnicí materiál(nie je nastavené)0.5-0.8 GAL/MIN, 1.9-3 L/MINSeřizovací mechanismusMaximální průtok
257,22 € / kus
FR101S185KonfiguraceTěsnicí materiál(nie je nastavené)1.6-2.2 GAL/MIN, 6-8.3 L/MINSeřizovací mechanismusMaximální průtok
304,63 € / kus
FR101S260KonfiguraceTěsnicí materiál(nie je nastavené)Rozsah zobrazení průtokuSeřizovací mechanismusMaximální průtok
290,00 € / kus
FR101S375KonfiguraceTěsnicí materiál(nie je nastavené)Rozsah zobrazení průtokuSeřizovací mechanismusMaximální průtok
162,93 € / kus
FR101S550KonfiguraceTěsnicí materiál(nie je nastavené)Rozsah zobrazení průtokuSeřizovací mechanismusMaximální průtok
136,35 € / kus
J02E2ZNReverse FlowTěsnicí materiálStandardní nastavení průtokuRozsah zobrazení průtokuSeřizovací mechanismusMaximální průtok
127,43 € / kus
J04C2ZNKonfiguraceTěsnicí materiálStandardní nastavení průtoku0.3-10.6 GAL/MIN, 1-40 L/MINSeřizovací mechanismusMaximální průtok
189,67 € / kus
J04E2ZNReverse FlowTěsnicí materiálStandardní nastavení průtoku0.3-10.6 GAL/MIN, 1-40 L/MINSeřizovací mechanismusMaximální průtok
111,64 € / kus