026-56111-H | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | Pilot line body: External from X (A-X closed / B-Y open) | (nie je nastavené) | A-B 4.0 bar, B-A 5.5 bar | NG10 / ISO 6264 | (nie je nastavené) | Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-56807-H | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | A-B 3.5 bar, B-A 6.0 bar | NG32 / ISO 6264 | (nie je nastavené) | Vent function: Solenoid not activated, unpressurized circulation, with manual override |
|
026-57539-H | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | (nie je nastavené) | A-B 3.5 bar, B-A 6.0 bar | (nie je nastavené) | (nie je nastavené) | Shuttle valve X-Y and vent function: Solenoid not activated, unpressurized circulation, with manual override |
|
026-62482-H | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | A-B 3.5 bar, B-A 6.0 bar | (nie je nastavené) | (nie je nastavené) | Vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-65920-H | Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | Pilot line body: External from X (A-X closed / B-Y closed) | (nie je nastavené) | A-B 4.0 bar, B-A 5.5 bar | NG10 / ISO 6264 | (nie je nastavené) | Vent function: Solenoid not activated, unpressurized circulation, with manual override |
|
026-66063-T | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 110/120 (VAC), 50/60 (Hz) | (nie je nastavené) | AA=0.95 AC, AB=0.05 AC | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | (nie je nastavené) | A-B 2.2 bar | NG32 / ISO 6264 | (nie je nastavené) | Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-66064-T | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 110/120 (VAC), 50/60 (Hz) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | NG32 / ISO 6264 | (nie je nastavené) | Vent function: Solenoid not activated, unpressurized circulation, with manual override |
|
026-66065-T | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 110/120 (VAC), 50/60 (Hz) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | A-B 3.5 bar, B-A 6.0 bar | NG32 / ISO 6264 | (nie je nastavené) | Vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-66316-H | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | (nie je nastavené) | A-B 0.6 bar, B-A 0.9 bar | NG32 / ISO 6264 | (nie je nastavené) | Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-66353-0 | Pilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closed | (nie je nastavené) | (nie je nastavené) | AA=0.95 AC, AB=0.05 AC | Pilot line body: External from Y (A-X orifice 1.2 / B-Y open) | (nie je nastavené) | A-B 2.2 bar | NG32 / ISO 6264 | (nie je nastavené) | (nie je nastavené) |
|
026-66426-H | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 24 (VDC) | (nie je nastavené) | AA=0.95 AC, AB=0.05 AC | (nie je nastavené) | (nie je nastavené) | A-B 2.2 bar | (nie je nastavené) | (nie je nastavené) | Vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-66602-0 | Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closed | (nie je nastavené) | (nie je nastavené) | AA=0.95 AC, AB=0.05 AC | (nie je nastavené) | (nie je nastavené) | A-B 2.2 bar | (nie je nastavené) | (nie je nastavené) | Shuttle valve Z-Y |
|
026-66827-T | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 110/120 (VAC), 50/60 (Hz) | (nie je nastavené) | AA=0.95 AC, AB=0.05 AC | (nie je nastavené) | (nie je nastavené) | A-B 2.2 bar | NG10 / ISO 6264 | (nie je nastavené) | Vent function: Solenoid not activated, unpressurized circulation, with manual override |
|
026-66963-H | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | A-B 3.5 bar, B-A 6.0 bar | (nie je nastavené) | (nie je nastavené) | Vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-67128-H | Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 24 (VDC) | (nie je nastavené) | AA=0.95 AC, AB=0.05 AC | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed) | (nie je nastavené) | A-B 2.2 bar | NG10 / ISO 6264 | (nie je nastavené) | Vent function: Solenoid not activated, unpressurized circulation, with manual override |
|
026-67252-0 | Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closed | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | Pilot line body: External from X (A-X closed / B-Y closed) | (nie je nastavené) | A-B 0.6 bar, B-A 0.9 bar | NG10 / ISO 6264 | (nie je nastavené) | (nie je nastavené) |
|
026-67435-S | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 230/240 (VAC), 50/60 (Hz) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | (nie je nastavené) | A-B 4.0 bar, B-A 5.5 bar | NG10 / ISO 6264 | (nie je nastavené) | Vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-67436-S | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 230/240 (VAC), 50/60 (Hz) | (nie je nastavené) | (nie je nastavené) | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | (nie je nastavené) | A-B 4.0 bar, B-A 5.5 bar | NG10 / ISO 6264 | (nie je nastavené) | Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override |
|
026-67640-U | Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | 230/240 (VAC), 50/60 (Hz) | (nie je nastavené) | AA=0.95 AC, AB=0.05 AC | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed) | (nie je nastavené) | A-B 2.2 bar | (nie je nastavené) | (nie je nastavené) | Vent function: Solenoid not activated, unpressurized circulation, with manual override |
|
026-67821-H | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | 24 (VDC) | (nie je nastavené) | (nie je nastavené) | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | (nie je nastavené) | A-B 3.5 bar, B-A 6.0 bar | NG32 / ISO 6264 | (nie je nastavené) | Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual override |
|