Logo
Your cart (1)

Košík je prázdny.

Single-Use Biopharm Temperature Sensors - SciLog® SciTemp®
Produkt #: SciTemp

SciLog® SciTemp® pre-calibrated temperature sensors combine accurate temperature measurement with the convenience of single-use. 5 different sizes are available. Calibration and identity information are stored on the sensor's gamma stable chip.

Typ připojení:
Def_Connection Type
Aplikace:
Temperature Sensing
Značka:
SciLog
Konstrukční materiály:
Medical Grade Polysulfone
Průmyslové odvětví:
Life Sciences
Technologie:
Process Control
Průmyslové odvětví:
Pharmaceuticals
Divize:
Bioscience and Water Filtration Division
Značka:
SciLog
Technické parametry splněny:
USP Class VI
Aplikace:
Temperature
Technické parametry splněny:
FDA 21 CRF 177.1520
Tube Size Range:
Def_Tube Size Range
Maximum Flow Rate (lpm):
Def_Maximum Flow Rate (lpm)
Maximum Pressure (psi):
Def_Maximum Pressure (psi)
Výkonnost:
Temperature Range: 4 to 70°C
Smáčený materiál:
Animal-Free Compounds

• Temperature can affect the performance of several applications during biopharmaceutical production and many critical filtration and separation applications are validated within a specific temperature range. This is particularly true of virus filtration, which needs to be operated under highly controlled conditions to guarantee the performance of the filtration. Parker domnick hunter's SciTemp® temperature sensors can monitor and control temperature in these critical applications ensuring the validated conditions are met.
• SciTemp® temperature sensors can also help to prevent protein denaturation due to temperature rises during the process, for example because of shear generated in pumps and across filtration membranes.
• Parker domnick hunter's range of SciLog® sensors is pre-calibrated and suitable for use in GMP applications, each carrying a unique ID, which stores the ID and calibration information. The sensors can be sterilized by autoclave sterilization.
• The availability of five connection sizes as well (Luer, 3/8” Barb, 1/2” Barb, 3/4" Tri-Clover and 1” Tri-Clover 'Ladish') as full NIST traceability means that SciTemp® sensors are fully scalable from development right through to GMP production.
Applications
• Growth Media Preparation
• Bioreactor Maintenance
• Cell Culture Harvest
• Buffer Preparation
• Product Filtration
• Tangential Flow Filtration
• Virus Control
• Bulk Drug Dispense
EAN kódTyp připojeníTube Size RangeMaximum Flow Rate (lpm)Maximum Pressure (psi)
080-794PSX-53/8" BarbID 0.31" to 0.38"(nie je nastavené)(nie je nastavené)
2.012,09 € / kus
080-795PSX-51/2" BarbID 0.50(nie je nastavené)(nie je nastavené)
2.042,16 € / kus
080-796PSX-53/4" Tri-Clover (TC)Tubing with 3/4" TC(nie je nastavené)(nie je nastavené)
2.303,80 € / kus
080-797PSX-51" Tri-Clover 'Ladish'Tubing with 1" TC Ladish(nie je nastavené)(nie je nastavené)
2.117,16 € / kus
080-799PSX-5LuerID 0.03" to 0.31"(nie je nastavené)(nie je nastavené)