Logo
Your cart (1)

Košík je prázdny.

Standard Pilot Vented Load Control Valves
Produkt #: MHC-010-VJND-00B

Parker’s vented load control valves are designed to operate independent of downstream pressure to prevent runaway loads under all dynamic conditions, handling pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm).
395,00 €

Těsnicí materiál:
Def_Seal Material
Těsnicí materiál:
Nitrile
Typ upevnění:
Def_Mounting Type
Poměr řídicího tlaku:
Def_Pilot Pressure Ratio
Velikost hrdla:
Def_Port Size
Typ upevnění:
Threaded Cartridge Valve
Rozsah řízení tlaku:
Def_Pressure Control Range
Poměr otevíracího tlaku:
10:1
Maximální průtok:
Def_Maximum Flow Rate
Maximální průtok:
10 GAL/MIN, 37.5 L/MIN
Seřizovací mechanismus:
Shimmed (non-adjustable)
Přidržovací tlak:
Def_Holding Pressure
Standardní nastavení tlaku:
1000 PSI, 69 BAR
Connection 2 Tube O.D. (inch):
N/A

Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.

Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated

Applications:
• Load holding
• Position holding

Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of  dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.