Logo
Your cart (1)

Košík je prázdny.

Připojení 1, velikost
Length (mm)
Connection 1 Thread Size (metric)
Hose I.D. (mm)
Permanent / Termination
Kód šoupátka
Connection Thread Size (inch)
Connection 2 Tube O.D. (inch)

LAC/LAC2 Standard Air Oil Cooler with AC-Motor (Europe)
Produkt #: LAC/LAC2 Standard Air Oil Cooler with AC-Motor

Suitable for most Industrial applications, the LAC air oil cooler series offers an efficient and robust design and is available in a range of cooling capacities from 1kW to 300 kW. Please use the sizing software for proper cooler sizing.

Dodatečné možnosti:
Def_Additional Options
Technologie:
Climate Control
ConfiguratorModelID:
LAC
Aplikace:
Thermal Management
Technologie:
Process Control
ConfiguratorOwnerID:
L12664
ConfiguratorType:
Parkereconfigurator
Divize:
Cylinder and Accumulator Division - Europe
Technologie:
Hydraulics
Nominal Size:
Def_Nominal Size
Connection Thread Size (inch):
Def_Connection Thread Size (inch)
Počet pólů motoru:
Def_Motor Pole Count
Input Voltage (AC):
Def_Input Voltage (AC)
Maximum Cooling Capacity (kW/°C):
Def_Maximum Cooling Capacity (kW)
Tlakový spád:
Def_Pressure Drop
Temperature Measurement Range (c):
Def_Temperature Measurement Range (c)
Pressure Relief Valve (bar):
Def_Pressure Relief Valve (bar)
Maximum Rated Pressure (bar):
Def_Maximum Rated Pressure (bar)

The Parker LAC air oil cooler series offers a reliable and efficient cooling system with the additional benefits of short lead times and 48 delivery for some part numbers. With its simple and robust design and wide selection of accessories this range will suit all industrial applications with a high voltage electric source.

The Parker LAC air oil cooler is quiet in operation and offers a low pressure drop and high cooling capacity. It has a single-phase or three-phase AC-motor and is also available in two special versions:
• With ATEX approval for use in potentially explosive atmospheres above ground (LAC-X series)
• With extra corrosion protection, for use in marine/offshore applications (MAC series)

The LAC size 200, which is unique on the market offers a cooling capacity of 300 kW at an estimated temperature difference of 40°C.

Markets:
• Oil and Gas
• Industrial
• Mobile
• Renewable Energy

Features/Benefits:
• Quiet fan and fan motor.
• Efficient and robust design which extends operating lifetime and reduces service and maintenance costs
• Cooler matrix with low pressure drop and high cooling capacity.
• Easy to maintain and easy to retrofit in many applications.

The correct working temperature produces a number of economic and environmental benefits:
• The hydraulic system’s useful life is extended.
• The oil’s useful life is extended.
• The hydraulic system’s availability increases – more operating time and fewer shutdowns.
• Service and repair costs are reduced
• High efficiency level maintained in continuous operation – the system’s efficiency falls if the temperature exceeds the ideal working temperature.

Applications:
• Power Units
• Lubrication Systems
• Marine Cranes
• Presses
• Wind Power

We have included a small selection of part numbers, for more options please download the LAC air oil cooler brochure or contact your local Parker sales office. Cooler product selector software to view 3D Models, product literature and sizing software is also available. You can also download our Cooler Sizing Software to select a cooler (in the Product Support tab).

Previously branded as Oiltech and Olaer.
EAN kódDodatečné možnostiNominal SizeConnection Thread Size (inch)Počet pólů motoruInput Voltage (AC)Maximum Cooling Capacity (kW/°C)Tlakový spádTemperature Measurement Range (c)Pressure Relief Valve (bar)Maximum Rated Pressure (bar)
5826033042(nie je nastavené)033(nie je nastavené)(nie je nastavené)230/400V 50Hz(nie je nastavené)2,6 bar at 250 l/min Oil flow, At 30 cStTemperature Switch 50°CBy-pass 2bar(nie je nastavené)
3.724,80 € / kus
5826033126(nie je nastavené)033(nie je nastavené)(nie je nastavené)230/400V 50Hz(nie je nastavené)2,6 bar at 250 l/min Oil flow, At 30 cSt(nie je nastavené)By-pass 5bar(nie je nastavené)
3.724,80 € / kus
5826033133(nie je nastavené)033(nie je nastavené)(nie je nastavené)265/460V 60Hz(nie je nastavené)2,6 bar at 250 l/min Oil flow, At 30 cStTemperature Switch 50°CThermal By-pass 50°C and By-pass 2.2 bar(nie je nastavené)
4.027,50 € / kus
5826044002(nie je nastavené)044(nie je nastavené)(nie je nastavené)265/460V 60Hz54 kW at delta T 40°C Oil flow 300 l/min3,1 bar at 350 l/min Oil flow, At 30 cStTemperature Switch 50°C(nie je nastavené)(nie je nastavené)
3.479,74 € / kus
5826044140(nie je nastavené)044(nie je nastavené)(nie je nastavené)230/400V 50Hz54 kW at delta T 40°C Oil flow 300 l/min3,1 bar at 350 l/min Oil flow, At 30 cSt(nie je nastavené)Thermal By-pass 50°C and By-pass 2.2 bar(nie je nastavené)
4.172,30 € / kus
5826056001(nie je nastavené)056(nie je nastavené)(nie je nastavené)230/400V 50Hz68 kW at delta T 40°C Oil flow 300 l/min2,8 bar at 300 l/min Oil flow, At 30 cStTemperature Switch 50°C(nie je nastavené)(nie je nastavené)
4.455,28 € / kus
5826056002(nie je nastavené)056(nie je nastavené)(nie je nastavené)265/460V 60Hz68 kW at delta T 40°C Oil flow 300 l/min2,8 bar at 300 l/min Oil flow, At 30 cStTemperature Switch 50°C(nie je nastavené)(nie je nastavené)
4.455,28 € / kus
5826056006(nie je nastavené)056(nie je nastavené)(nie je nastavené)230/400V 50Hz68 kW at delta T 40°C Oil flow 300 l/min2,8 bar at 300 l/min Oil flow, At 30 cSt(nie je nastavené)Thermal By-pass 50°C and By-pass 2.2 bar(nie je nastavené)
4.764,56 € / kus
5826056067(nie je nastavené)056(nie je nastavené)(nie je nastavené)265/460V 60Hz68 kW at delta T 40°C Oil flow 300 l/min2,8 bar at 300 l/min Oil flow, At 30 cSt(nie je nastavené)(nie je nastavené)(nie je nastavené)
4.455,28 € / kus
5826056068(nie je nastavené)056(nie je nastavené)(nie je nastavené)230/400V 50Hz68 kW at delta T 40°C Oil flow 300 l/min2,8 bar at 300 l/min Oil flow, At 30 cSt(nie je nastavené)By-pass 5bar(nie je nastavené)
4.800,16 € / kus
5826056080(nie je nastavené)056(nie je nastavené)(nie je nastavené)230/400V 50Hz68 kW at delta T 40°C Oil flow 300 l/min2,8 bar at 300 l/min Oil flow, At 30 cStTemperature Switch 50°C(nie je nastavené)(nie je nastavené)
4.580,31 € / kus
5826056142(nie je nastavené)056(nie je nastavené)(nie je nastavené)265/460V 60Hz68 kW at delta T 40°C Oil flow 300 l/min2,8 bar at 300 l/min Oil flow, At 30 cSt(nie je nastavené)By-pass 5bar(nie je nastavené)
4.823,80 € / kus
5826058003(nie je nastavené)058(nie je nastavené)(nie je nastavené)265/460V 60Hz68 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cSt(nie je nastavené)(nie je nastavené)(nie je nastavené)
4.659,27 € / kus
5826058027(nie je nastavené)058(nie je nastavené)(nie je nastavené)230/400V 50Hz72 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cSt(nie je nastavené)(nie je nastavené)(nie je nastavené)
4.836,97 € / kus
5826058055(nie je nastavené)058(nie je nastavené)(nie je nastavené)265/460V 60Hz72 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cSt(nie je nastavené)(nie je nastavené)(nie je nastavené)
4.751,41 € / kus
5826058061(nie je nastavené)058(nie je nastavené)(nie je nastavené)230/400V 50Hz72 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cSt(nie je nastavené)By-pass 2bar(nie je nastavené)
6.379,64 € / kus
5826058109(nie je nastavené)058(nie je nastavené)(nie je nastavené)230/400V 50Hz72 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cSt(nie je nastavené)Thermal By-pass 50°C and By-pass 2.2 bar(nie je nastavené)
5.236,17 € / kus
5826058128(nie je nastavené)058(nie je nastavené)(nie je nastavené)230/400V 50Hz68 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cSt(nie je nastavené)Thermal By-pass 50°C and By-pass 2.2 bar(nie je nastavené)
5.348,17 € / kus
5826058141(nie je nastavené)058(nie je nastavené)(nie je nastavené)230/400V 50Hz72 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cStTemperature Switch 60°CBy-pass 5bar(nie je nastavené)
5.040,01 € / kus
5826058142(nie je nastavené)058(nie je nastavené)(nie je nastavené)265/460V 60Hz68 kW at delta T 40°C Oil flow 300 l/min2 bar at 400 l/min Oil flow, At 30 cSt(nie je nastavené)By-pass 5bar(nie je nastavené)
5.266,64 € / kus